Fleck water softener parts fleck water softener rebuild fleck water softener parts for 2750 2850 2850s 2900s 3150 3900 valve material fiber water softener parts, valves, and water filters fleck, 56sxtservicemanualdownflow42684revg. Fleck manuals water softeners control heads set up and repair instructions. If piping is clogged with iron, a separate iron filter unit should be installed ahead of the water softener. This operations manual should then be kept near the device and used as a reference and troubleshooting guide. How to rebuild a water softener valve fleck 2510 part 2 of 2 duration. Currently, certain supply chains may be affected resulting in delays. The brine valve drive cam will hold the valve in this position to fill the brine tank for the first regeneration. Hardness minerals are drawn to the resin beads in the softener. If storage tank is subject to vacuum, an adequate vacuum relief valve must be properly. Your new system comes with a printed fleck service manual, turn off water to the fleck 7000 and relieve the water pressure by opening up a faucet in the house. The fleck 2850 is a solidly constructed, leadfree brass valve body for superior strength and durability.
The 2850 valve body is offered in the classic mechanical design for rugged construction and simple operation, as well as in the 2850sxt electronic programmable style for. Water control sf series softeners feature 1 service connections. Place the header in the service position and cycle the valve to the backwash position. Fleck valves are also available in metered options for ondemand regeneration based on the volume of water that has been used. Fleck 2850 control valves for water softeners and media. Drain cannot be elevated more than 36 inches or exceed 20 feet in length. To change the length of refill time, move the two pins at the end of the second group of holes as required. During backwash, the water flow is reversed and water flows down the distributor tube and up through the media. Well be glad to help you find the right size, call 18883092837 or order online at the reverse osmosis superstore. Ensure water goes into the brine tank at the desired rate.
Jan 23, 2019 how to manually regenerate a fleck 2850 control head. Fleck nxt2 timer service manual waterpurification table of contents. Jan 24, 2019 fleck 2850 setting regeneration time and time of day. Fleck 2850 commercial water softener 55 gpm water softener.
Featuresbenefits leadfree brass valve body for superior strength and durability continuous service flow rate of 70 gpm with a backwash of 70 gpm backwash capability accommodates softener tanks up to 36 and filter up to 30 in diameter fully adjustable 3 or 5cycle control for efficient and reliable water treatment system designed for single or multiple tank systems environmental protective. This manual is a reference and will not include every system installation situation. Up guide thank you for purchasing a clean water system. Water softener or filter control valve 36 pages control unit pentair autotrol 740 service manual. Download copy of fleck 2850 service manual the 2850 sold previously and currently valve is different than the 2850s, sold 2008 2018 shown below. Fleck control valves automatically control the backwash and regeneration cycles for media filters and water softeners to keep your water treatment. If the valve came with a separate electronic timer service manual, refer to the timer operation. Fleck 2850 control valve service manual lakeside water treatment.
Genesis revolution maximum flow water softener system. Fleck 2850s service manual 42319 rev e oc11 table of contents. View and download pentair fleck 2850 service manual online. The water softener should be installed with the inlet, outlet, and drain connections made in. The resin is left full of sodium to enable it to soften water again. Your new system comes with a printed fleck service manual. Then, connect according to the local plumbing codes.
Fleck 2850 setting regeneration time and time of day. The fleck 2850s is a rugged commercial water softener valve with the advanced nxt digital control and electronic meter. We are currently monitoring the impact of covid19 around the world. Manuals discount water softeners genesis, fleck, iron. Fleck model 2850 sxt series operation and service manual. View and download pentair fleck 2850s service manual online. The water softener should be installed with the inlet, outlet, and drain connections made in accordance with the. Locate the dealkalizer close to a clean working drain after the water softener and prior to carbon tanks. You can also filter by type, model, water softener and country region of manufacture or opt for one of our fleck water softener editorial picks. Softener filter fleck model 2850 sxt medical industrial series operation and service manual. Fleck manuals water softeners control heads set up. Fleck 2850 112 valves, a 112 top mounted control valve ideal for smallersize commercialindustrial applications. Fleck 9100 sxt twinalternating metered water softener. Detailed drawings also available upon request cad or revit.
Make plumbing connections to the fleck 2850 sxt valve. Fleck 2850 control valves for water softeners and media filters. The fleck 2850 commercial water softener is a fully adjustable, 5cycle metered water softener it is a timetested hydraulically balanced piston, seal and spacer design to pilot service flow and regeneration. Buy products related to fleck water softener parts and see what customers say about fleck water softener parts on free delivery possible on eligible purchases. Let the water flow slowly into the mineral tank until the air is purged from the system. Flecks 2850 valve is ideal for commercial filters and water softeners up to 24 to 30 diameter tank size.
Missplaced or lost user manuals are no longer an issue. The water softener should be installed with the inlet, outlet, and drain connections made in accordance with the manufacturers recommendations, and to meet applicable plumbing codes. Fleck control valves automatically control the backwash and regeneration cycles for media filters and water softeners to keep your water treatment system working at optimal performance all the time. Turn the manual regeneraton knob slowly in a clockwise. Your new system comes with a printed fleck service manual, which along with this start. Fleck 2750 control valves for water softeners and media. We are your trusted source for fleck 2850 control valves for commercialindustrial softeners and media filters. Fleck 2850 control valve service manual 16510 rev k oc11 table of contents.
Aqua science offers fleck backwash and water softener control valves available in the digital, econominder, 12 day timer and tin demand models of the 5600, 2510 and the 9100. The 2850 valve body is offered in the classic mechanical design for rugged construction and simple operation, as well as in the 2850sxt electronic programmable style for an extended range of settings and options capabilities. Fleck 900091009500 service manual 5 changing length of brine tank refill time the second group of holes on the program wheel determines the length of time the water conditioner refills the brine tank 2 minutes per hole. Installer manual fleck 2850 sxt generalities 8 106 ref. Fleck 2850 control valve, water softenrer, water softener parts, buy fleck control valve, fleck 2850 replacement parts, water softener replacement parts click on the diagram images below to buy the products by part number. Follow the links bellow to access the pentair user manual you need. Valves control valves controllers for valves tanks and systems boosting pressure tanks pressure vessels softener systems. Where to find the manual for your water conditioner or water softener. Fleck 2850 control valves for softeners and media filters applied. We inspected 12 finest fleck water softeners over the recent 2 years. How to manually regenerate a fleck 2850 control head. Fill in pertinent information on page 3 for future reference.
With proper installation and a little routine maintenance your system will be providing filtered water for many years. Place the softener tank where you want to install the unit making sure the unit is level and on a firm base. The 2850 valve body is offered in the classic mechanical design for rugged construction and simple operation. For a detailed, modelspecific specification, please contact water control corporation. Water softening system requires a minimum inlet water pressure of 30 psig and maximum of 120 psig. Fleck manuals water softeners control heads set up and. Water softener parts, valves, and water filters fleck, ge osmonics autotrol, sears north star and other brands. The brine tank should be located within 20 feet of the water softener. Fleck 2850 setting regeneration time and time of day youtube. This unit is designed to be installed on potable water systems only. Fleck 2850 features fully adjustable 5cycle control delivers controlled up. Plug the fleck 2850 sxt control valve into a 120volt gfi receptacle.